Q: Can a fan/light/heater unit be placed on the same circuit as the required 20-amp receptacles in a bathroom, or does it need to have its own separate circuit?

info-584-445

A: Lynn Underwood, engineer, licensed contractor, and building code official for the City of Norfolk, Virginia, answers: 2015 IRC Section E3703.4 requires at least one 20-amp circuit to power GFCI-protected receptacles in a bathroom. While receptacles in other rooms cannot be placed on this circuit, other small devices in a bathroom, such as exhaust fans, may be placed on this circuit, per code-but only if the circuit only powers one bathroom. Therefore, a combination unit placed on a circuit may technically meet code.

 

In practice, however, electricians almost always add a separate circuit that matches the vent fan motor rating and the unit's heat light (or blower) needs to avoid recalls due to tripping faults. A 20-amp circuit can safely supply 80% of the load, or 1,920 watts, before risking a trip (20 amps x 120 volts = 2,400 watts; 2,400 x .80 = 1,920). An average-sized hair dryer is typically rated at 1,000 watts, and a curling iron is rated even higher; plug them in and turn them on at the same time, and you've exceeded the safe capacity of the circuit without even turning on the combined unit. That's why some manufacturers designate dedicated circuits (which don't require GFCI protection) for some of their combined units.

 

Not only is it good practice to wire separate circuits, but IRC Section E3601.2 states that the ampacity of a branch circuit must be equal to the load expected on the circuit. Installations must comply with all sections of the code, not just one provision.

Send Inquiry
Send Inquiry